Three-minute technical briefing, on brand (Catalyst register, Vortex™ mark, Audiowide wordmark), explaining the Module and its dynamic range: floor, target, sustained ceiling, peak and failover.

Doc No.CBT-MOD-VID-001
RevisionDesign Zero
StatusDESIGN ZERO — WORKING DESIGN, UNLOCKED
ClassificationISC-2 Confidential
Baseline100 TPD Module · carbon route W1
Design Zero
DESIGN ZERO — WORKING DESIGN, UNLOCKED. Design Zero is unlocked; the Architect locks it when the time is right. Every earlier locked record this design touches is unlocked by CBT-TB-PORTAL-014, not amended. Provenance tags [RULED] [COMPUTED] [INFERRED] [OPEN] [PROPOSED] are kept; under Design Zero a [RULED] tag means ruled by the Architect for Design Zero, not locked. OPEN values are not filled.
Document Control
Document NumberCBT-MOD-VID-001
DesignDesign Zero · 100 TPD Module
Document StatusDESIGN ZERO — WORKING DESIGN, UNLOCKED
OwnerCarbotura Inc. — Engineering; Allen Witters, Lead Systems Architect
ClassificationISC-2 Confidential
AuthorityCBT-TB-PORTAL-014 (Architect, 2026-11-04)
Mediaassets/video/mod-vid-001-technical-briefing.mp4 (21 MB, 1920 × 1080, 30 fps) and .vtt captions
BuiltSynthesia, Carbotura workspace, 2026-11-03; script CRSRU_HEAT_SOURCE_DESIGN/EXPLAINER_VIDEO_SCRIPT_V2.md

1. The briefing

Technical briefing on the 100 TPD Module for engineering and manufacturing: what it is, what it makes, and its dynamic range from the 30 TPD floor through the 100 TPD target to the 165 to 200 TPD ceiling and the failover case. 3:00, 1920 × 1080, Catalyst register, captions on. Served from this portal only, behind the Access gate; no share page exists.

Captions are generated from the storyboard timings (11 cues). The on-screen captions of the render are burned in as well.

2. What the briefing states

SettingTPDPower at the busWhat sets it
Floor30about 4 MWeach Line at about 15 %, torch pilot arc and N₂ loop; both Lines always run
Target100about 10 MWhalf of what the frames can do; every frame rated for 200
Sustained ceiling165 to 20016 to 22 MW installedfuel cells; carbon route
Peak200, 1 to 2 habout 19 MWBESS 5 MWh / 2 MW and the 4 h hydrogen buffer
Failover100 on one Line—the other Line carries the Module on its 2× rating; no standby units; headroom is the failover

3. Appendix — script and storyboard, as built

Draft 2 of the explainer script, as built in the Carbotura Synthesia workspace (video id e803fc40-59d8-42f4-ab97-352da467bb2c). Draft 1 is superseded and is not published.

Sub-session: CRSRU heat-source design · Date: 2026-11-03 · For: Allen Witters, Lead Systems Architect Classification: ISC-2 Confidential · Audience: internal engineering and manufacturing · Length: 3 min 00 s (Syren's ceiling; the Architect's range was 3 to 5 minutes, so this is the lower bound) · Delivery: MP4 hosted behind docs.carbotura.com; not a share link Status: draft 2 built in the Carbotura Synthesia workspace with Syren on 2026-11-03: video "100 TPD Module — technical briefing", id e803fc40-59d8-42f4-ab97-352da467bb2c, exactly 3:00, 16:9, captions in Inter, preview render 960 × 540; presenter "Helen", voice "Alice" (British); Audiowide, Inter and JetBrains Mono fetched from Google Fonts; the Vortex mark drawn from the canonical path in flat white at 160 px on the cards and 28 px in the scene corners; colours the Catalyst hex values only, series in the fixed order, every band labelled. Held in My Videos, not shared and not published; full-quality export awaits the Architect's review. Supersedes: draft 1 (EXPLAINER_VIDEO_SCRIPT.md, built as video 8747f145-…, kept) Source of record: MODULE_100TPD_DEFINITION.md §9, §12.7, §15, §18, §20, §22, §23; OPERATING_ENVELOPE.html

A1. Brand, from https://brand.carbotura.com/brand.json (CRBT-BRAND-ARCH v2.1, canon release 122, tokens pin 13)

brand.json is the authority (Architect directive 2026-08-18); where it and _global/BRAND_IDENTITY.md differ, brand.json wins. One difference noted: BRAND_IDENTITY carries a two-colour CARBO/TURA wordmark pattern for page chrome; brand.json's logo rule is the wordmark "Carbotura®" in Audiowide Regular. The video uses brand.json's form.

Element Value applied
Register Catalyst, dark (web and engineering surface; "Audiowide at hero scale, Mono renders the technology as engineering readouts, Inter for body")
Grounds base #0C1424, surface #1B2745, raised cards #232D4A, divider #525E78
Text ink #FFFFFF, heading #DCE2F0, body #AEB8CC, muted #8B95AC; violet as text only in its ink step #9C90E8
Accent Catalyst violet #8B5CF6 for UI and large elements; blue #007FFF
Chart and diagram series, in this order, never cycled 1 blue #007FFF · 2 orange #EA580C · 3 teal #0D9488 · 4 violet #9333EA · 5 pink #DB2777 · 6 olive #65A30D; no data encoded by colour alone (S-06): every band and bar is labelled
Signal #FB923C only as a labelled pill, never a data colour, never the mark (S-01, S-03); not used in this video
Vortex™ mark the canonical SVG path from brand.json, viewBox 0 0 1024 1024, passed to Syren verbatim; white fill on the dark base (master colourway), flat, no shadow, never rotated or stretched; clear space 0.5× its width; never below 20 px
Wordmark "Carbotura®" in Audiowide Regular, ink white, beside the mark on the title and end cards; mark alone at small size in the corner of diagram scenes
Typefaces Audiowide: title, scene headlines, wordmark only · Inter: body, labels, captions · JetBrains Mono: every numeric readout (TPD, MW, °C, kW, hours)
Vocabulary brand.json terminology applied: "feedstock receiving bay" replaces the retired receiving-floor term; "Island Mode (grid-independent)"; "elemental dissociation"; "near-zero-emission manufacturing" is the one permitted use of that word; "Circular Materials"; hydrogen is internal fuel, never a product; no retired fuel-cell term

Flag for the package: MODULE_100TPD_DEFINITION.md §14 and the HTML page used the retired receiving-floor and receiving-lane terms throughout; brand.json's terminology table (canon 122) lists the former receiving-floor term under never-use, with "Feedstock receiving bay (enclosed, airlocked)" as the term. A sweep of the package is needed; not done in this draft.

A2. Narration rules

Figures spoken are ruled or computed values from the Module file; the design-point energy balance is "within a megawatt" because its exact value is OPEN pending the simulator sweep (§21). 420 words at 140 words per minute; Syren is told the hard limit is 3:00 including the fade.

A3. Storyboard (11 scenes)

# Time Scene Narration (spoken) On-screen (Audiowide headline · Inter labels · Mono readouts) Visual
1 0:00–0:08 Title "The one-hundred-tonne-per-day Module: what it is, what it makes, and how far it turns up and down." Vortex™ mark · Carbotura® · 100 TPD Module · technical briefing base ground, mark white, wordmark in Audiowide
2 0:08–0:25 Architecture "Two Lines, run at the same setpoint. Four Recyclotron reactors, two per Line. One shared feed-distribution frame upstream, one cold-gas header downstream. A fifteen-hundred-volt DC bus fed by solid-oxide fuel cells. Island Mode: no grid connection, ever." Architecture · 2 Lines, equal dispatch · 4 Recyclotron™ reactors · 1,500 VDC · Island Mode block diagram on the surface colour: FDS → Line A / Line B → cold-gas header → fuel cells → bus loop; mark small in the corner
3 0:25–0:47 Process "Feed is dried to five percent and sized in Pregenesis. The Recyclotrons dissociate it at five hundred and fifty to six hundred degrees. The CRSRU plasma torch, above thirteen hundred degrees, takes every hydrocarbon to carbon and hydrogen: pristine carbon black is caught at the quench; the syngas feeds the fuel cells." Process · Pregenesis™ 5 % · Recyclotron™ 550–600 °C · CRSRU >1,300 °C · carbon black · syngas four blocks lighting in series 1 blue as named; readouts in Mono
4 0:47–1:02 Products "Day one sells eight products: carbon black, bed char, industrial CO₂, ferrous, a non-ferrous concentrate, an aggregate mineral concentrate, pozzolanic cement powder, and industrial water. Hydrogen is internal fuel, never a product." Day-1 Circular Materials · 8 tiles · H₂: internal fuel eight tiles appearing one per name; an H₂ tile inside a dashed fence line
5 1:02–1:24 The floor "Now the dynamic range. Each Line turns down to about fifteen percent, set by the torch pilot arc and the nitrogen loop. Both Lines always run, so the Module floor is thirty tonnes a day. Below fifty the fixed loads dominate and the buffers carry the balance: a floor to pass through, not to live in." Dynamic range: the floor · Line floor ~15 % · Module floor 30 TPD · 30–50 TPD transient a range bar 0 to 200 TPD; the floor marker at 30; a labelled band 30–50 "transient"
6 1:24–1:50 Target and ceiling "The target is one hundred, half of what the frames can do; every frame is rated for two hundred. The fuel cells, sixteen to twenty-two megawatts installed, set the sustained ceiling: one hundred sixty-five to two hundred tonnes a day on the design point. Two hundred is the hard ceiling: frame ratings, and the reactor cap of six hundred kilowatts, uprated to one-point-two megawatts." Target and ceiling · target 100 TPD · frames 2× · fuel cells 16–22 MW · sustained 165–200 TPD · ceiling 200 TPD · reactor 600 kW, uprate 1.2 MW the same bar: target marker in series 1 blue, sustained band in series 2 orange, hard ceiling line at 200, each labelled
7 1:50–2:10 Peaks and failover "Above that, the Module peaks at two hundred for one to two hours on the battery and the four-hour hydrogen buffer. Lose one Line's hot train, and the other carries the Module at one hundred on its two-times rating. No standby units: the headroom is the failover." Peak and failover · peak 200 TPD, 1–2 h · BESS 5 MWh · H₂ buffer 4 h · failover: one Line at 100 · no standby the bar with a labelled peak; then two Line bars, one dimming while the other doubles
8 2:10–2:27 How it moves "Power follows throughput: four megawatts at the floor, ten at target, nineteen at two hundred, moved in layers: battery in seconds, reactors and torches in minutes, fuel cells over an hour, batch loads over the day against the hydrogen inventory." Modulation · 4 MW floor · 10 MW target · 19 MW at 200 · seconds · minutes · hour · day a load-versus-throughput line in series 1; four timescale bars in a column, labelled
9 2:27–2:44 Heat and water "Heat is cascaded before it is rejected: CO₂ liquefaction, plasma-gas preheat, a steam turbine. The Module makes more water than it uses. The design-point balance sits within a megawatt, carried by the buffers while the simulator settles the feed energy." Heat cascade · CO₂ liquefaction · preheat · steam cycle · net water producer · balance within 1 MW a short ribbon diagram: heat pool → three uses → to air
10 2:44–2:56 Stages "Day one is the eight products. Phase two adds the graphitiser. A four-Module facility adds a shared finishing hall. Gen 2 replaces the nitrogen loop with hydrogen plasma." Stages · 1 Day-1 · 2 graphitiser · 3 facility · 4 Gen 2 four raised cards
11 2:56–3:00 Close "The envelope and the rulings are on the engineering portal." Vortex™ mark · Carbotura® · docs.carbotura.com · design definition, not a ruling base ground end card, no fade beyond 3:00

A4. Narration, continuous (420 words)

The one-hundred-tonne-per-day Module: what it is, what it makes, and how far it turns up and down.

Two Lines, run at the same setpoint. Four Recyclotron reactors, two per Line. One shared feed-distribution frame upstream, one cold-gas header downstream. A fifteen-hundred-volt DC bus fed by solid-oxide fuel cells. Island Mode: no grid connection, ever.

Feed is dried to five percent and sized in Pregenesis. The Recyclotrons dissociate it at five hundred and fifty to six hundred degrees. The CRSRU plasma torch, above thirteen hundred degrees, takes every hydrocarbon to carbon and hydrogen: pristine carbon black is caught at the quench; the syngas feeds the fuel cells.

Day one sells eight products: carbon black, bed char, industrial CO₂, ferrous, a non-ferrous concentrate, an aggregate mineral concentrate, pozzolanic cement powder, and industrial water. Hydrogen is internal fuel, never a product.

Now the dynamic range. Each Line turns down to about fifteen percent, set by the torch pilot arc and the nitrogen loop. Both Lines always run, so the Module floor is thirty tonnes a day. Below fifty the fixed loads dominate and the buffers carry the balance: a floor to pass through, not to live in.

The target is one hundred, half of what the frames can do; every frame is rated for two hundred. The fuel cells, sixteen to twenty-two megawatts installed, set the sustained ceiling: one hundred sixty-five to two hundred tonnes a day on the design point. Two hundred is the hard ceiling: frame ratings, and the reactor cap of six hundred kilowatts, uprated to one-point-two megawatts.

Above that, the Module peaks at two hundred for one to two hours on the battery and the four-hour hydrogen buffer. Lose one Line's hot train, and the other carries the Module at one hundred on its two-times rating. No standby units: the headroom is the failover.

Power follows throughput: four megawatts at the floor, ten at target, nineteen at two hundred, moved in layers: battery in seconds, reactors and torches in minutes, fuel cells over an hour, batch loads over the day against the hydrogen inventory.

Heat is cascaded before it is rejected: CO₂ liquefaction, plasma-gas preheat, a steam turbine. The Module makes more water than it uses. The design-point balance sits within a megawatt, carried by the buffers while the simulator settles the feed energy.

Day one is the eight products. Phase two adds the graphitiser. A four-Module facility adds a shared finishing hall. Gen 2 replaces the nitrogen loop with hydrogen plasma.

The envelope and the rulings are on the engineering portal.

A5. Before publishing

  1. Architect review in the player; the range figures are from §9.1, §9.6, §12.7, §15.1, §15.5 and §20.
  2. Brand check against brand.json (applied above); publish audit on the title and end cards.
  3. Full-quality export, MP4 behind the portal; no share link (ISC-2).
  4. The receiving-term sweep of the package (done 2026-11-03).