Clean-Sheet Route for Maximum Hydrogen and Carbon from the Feedstock (Rev 1)
Rev 1 working file of the CRSRU heat-source sub-session, rendered as written; linked from MOD-DEF-001 §4.2. File name kept as the page title: CLEAN_SHEET_H2_CARBON.md.
| Document Number | CBT-MOD-CRSRU-006 |
| Design | Design Zero · 100 TPD Module |
| Document Status | DESIGN ZERO — WORKING DESIGN, UNLOCKED |
| Owner | Carbotura Inc. — Engineering; Allen Witters, Lead Systems Architect |
| Classification | ISC-2 Confidential |
| Authority | CBT-TB-PORTAL-014 (Architect, 2026-11-04) |
| Source of record | CRSRU_HEAT_SOURCE_DESIGN/CLEAN_SHEET_H2_CARBON.md on main |
| Sub-session | CRSRU heat-source design · |
| Date | 2026-11-02 (Rev 1 reconciles the duty and yields with |
| Status | DESIGN PROPOSAL — not a ruling. Written on the Architect's direction of 2026-11-02: *the CRSRU |
- 1. What the feed contains — the budget nothing can exceed [COMPUTED]
- 2. The water split — three routes [COMPUTED]
- 3. The energy ledger — the finding that frames everything [COMPUTED…
- 4. The optimized route — "water around the carbon" (W1) [INFERRED d…
- 5. Product makeup per Line and per Module (W1) [COMPUTED]
- 6. Contamination under this route
- 7. Levers if the ~2.6–3 MW per Line deficit must close without exte…
- 8. What this route reopens (rulings, not for this sub-session)
- 9. Open items this proposal carries
Sub-session: CRSRU heat-source design · Date: 2026-11-02 (Rev 1 reconciles the duty and yields with
00_DESIGN_BASIS_COMMON.md Rev 1: Boudouard term added, full CH₄ load, carbon and H₂ figures restated)
For: Allen Witters, Lead Systems Architect · Classification: ISC-2 Confidential
Status: DESIGN PROPOSAL — not a ruling. Written on the Architect's direction of 2026-11-02: the CRSRU
dissociates every hydrocarbon in the vapour to carbon and hydrogen; the priority is hydrogen and carbon
products.
Provenance tags: [RULED] [COMPUTED] [INFERRED] [OPEN]. All figures per Line at 50 TPD on the model's reference feed, element basis, Class 4. Canon note: hydrogen is Island-Mode internal fuel, never a product (Doctrine); this file says "hydrogen to the PowerBlock" and "carbon products".
1. What the feed contains — the budget nothing can exceed [COMPUTED]
Per Line, 2,083 kg/h as received: moisture 23.7 %, mineral 10.2 %, dry-ash-free organic 1,377 kg/h.
Carbon 18.15 mol/s (785 kg/h); hydrogen 14.8 mol/s H₂-equivalent (107 kg/h); organic oxygen 7.87 mol/s
(453 kg/h); moisture 7.61 mol/s (494 kg/h). Full table in 00_DESIGN_BASIS_COMMON.md §2.
The oxygen disposition rule. 453 kg/h of oxygen must leave bound to something. As CO₂ it costs 0.5 C per O; as CO, 1 C per O; as H₂O, 2 H per O. Every mol of water that reacts with carbon trades one carbon atom for two H₂ (one in the CRSRU, one at the shift). That trade is the only dial.
2. The water split — three routes [COMPUTED]
The Recyclotron™ forms ~4.8 mol/s of reaction water from organic oxygen regardless of feed moisture; it reaches the CRSRU with the tars and reacts with carbon there. Feed moisture can be dried off in Pregenesis™ and re-used as WGS steam, where it cannot touch solid carbon.
| Route | Water reacting with carbon in the CRSRU | Carbon product | H₂ to PowerBlock | CO₂ co-manufactured | H₂ as electricity at 55 % PEM |
|---|---|---|---|---|---|
| W0 — theoretical ceiling, no water reacts (not reachable) | 0 | 650 kg/h | 85 kg/h | 190 kg/h | 1.6 MW |
| W1 — feed dried to ~5 %; reaction water and residual react; dried-off moisture to the WGS | 6.35 mol/s | 380 kg/h (18 % of feed) | 163–186 kg/h (7.8–8.9 %) | 1,070–1,485 kg/h | 3.0–3.4 MW |
| W2 — no drying; all water through the CRSRU; WGS on boiler steam | 12.5 mol/s | 115 kg/h | 275 kg/h | 2,440 kg/h | 5.0 MW |
W1 keeps 3.3× the carbon of W2 and gives 60–70 % of its hydrogen. §3 shows why W2 does not buy what it appears to buy.
3. The energy ledger — the finding that frames everything [COMPUTED / INFERRED]
Electrical demand per Line, Option C heater at CENTRAL duty (1,400 °C), N₂ loop, candle filter:
| Load | W1 | W2 | Basis |
|---|---|---|---|
| Recyclotron™ magnetrons, 2 × 300 kW at 83 % | 0.72 MW | 0.72 MW | published 720 kW per 600 kW |
| CRSRU heater (2.2 / 3.0 MW thermal ÷ ~0.58 incl. N₂ heating) | 3.8 MW | 5.2 MW | C_DC_TORCH_BASELINE.md |
| N₂ loop, candle filter | 0.1 MW | 0.1 MW | |
| GPU/WGS gas compression from 0.5 atm to ~8 bar (~2,900 Nm³/h) | 0.9 MW | 1.3 MW | 0.3 kWh/Nm³ |
| Pregenesis™ mechanical and drying auxiliaries (drying heat from recovered steam) | 0.3 MW | 0.2 MW | [INFERRED] |
| APS, controls, misc. | 0.2 MW | 0.2 MW | [INFERRED] |
| Demand | 6.0 MW | 7.7 MW | |
| Supply from the Line's own hydrogen at 55 % PEM | 3.0–3.4 MW | 5.0 MW | §2 |
| Deficit | 2.6–3.0 MW | 2.7 MW |
Converting carbon to hydrogen through an electrically heated CRSRU is almost energy-neutral. One mol of carbon reacted with steam yields 2 H₂ (484 kJ chemical, ~266 kJ electric at 55 % PEM) and costs 131 kJ of endotherm at ~58 % heater efficiency (~226 kJ electric). Net gain ~40 kJ per mol of carbon destroyed: ~0.04 MW per 100 kg/h of carbon. W2 destroys 265 kg/h of carbon per Line and the deficit does not move. Carbon is nearly free to keep.
Island-Mode self-sufficiency at 50 TPD per Line is not reachable from this feed at any carbon yield with a plasma-heated CRSRU. The feed carries 8.4 MW of chemical energy per Line; at 55 % PEM the ceiling is 4.6 MW electric with zero carbon product, below the 6 MW demand. This is D-ACM-ENERGY-01's calorific floor made concrete. The gap closes with the levers in §7, with a higher-LHV feed envelope, or with external power of ~2–3 MW per Line (16–24 MW per 400 TPD facility). Which, is a ruling.
4. The optimized route — "water around the carbon" (W1) [INFERRED design]
Pregenesis™ drying (recovered steam) ──dried-off moisture 6.1 mol/s──────────────┐ (as WGS steam)
│ dry feed (~5 % moisture), 13 mm, admix │
Recyclotron™ ×2 (dry, recycled-H₂ carrier, no bed steam, 550–650 °C, 0.5 atm) │
│ char 195 kg/h + mineral 212 kg/h → OmniCrude™ Solids → separation │ carbon product 1
│ vapour 1,290 kg/h: hydrocarbons + reaction water + CO/CO₂ + H₂ │
Primary Cyclone → REG-CCS-001 │ carbon product 2 (pristine fines)
│ [hot-gas booster 0.5 → 1.2 atm — option] │
CRSRU dissociation reactor, 1,300–1,400 °C, 0.5–2 s, 2.0–2.2 MW thermal │
│ H₂ 16.3 + CO 9.4 mol/s (+ N₂ 9.5 if DC torch) + 185 kg/h carbon black │
Quench boiler (fast through 1,200 → 700 °C) → steam to drying and WGS │
HRSG → candle filter → CRSRU carbon black → metals separation │ carbon product 3
Condenser (little water) → acid-gas removal (HCl, H₂S) │
Water Gas Shift ◄──────────────────────────────────────────────────────────────────┘
CO₂ removal → PSA → H₂ 163–186 kg/h to Zero-E PowerBlock™ ; N₂ → loop ; CO₂ → buffer
4.1 Pregenesis™ — the carbon decision is made here
Dry to ≤5 % moisture on quench-boiler/HRSG steam: 0.36 MW thermal per Line to evaporate 494 kg/h; the recovery streams are 1–2 MW per Line. The Trough 2 paddle dryers already run on quench steam per Devin's acknowledgment. Target moisture is OPEN; the case matrix's moisture axis is the sweep that sets it. The dried-off water is the WGS steam supply.
4.2 Recyclotron™ — clean-sheet changes for downstream
| Change | Why | Reopens |
|---|---|---|
| No bed steam injection | 2.2 mol/s of steam per Line would react with carbon in the CRSRU: −95 kg/h carbon, +32 kg/h H₂, ~zero net energy | D-MCR-FLOW-01 |
| Recycled H₂ as purge, airlock and dense-phase injection gas instead of N₂ | Non-dilutive; nothing new at the GPU; carbon methanation (C + 2 H₂ → CH₄) is slow and disfavoured at 550–650 °C and 0.5 atm | D-46, the Dense-Phase N₂ Pneumatic Injection System name |
| Freeboard at the hot end (650 °C, 400 kW zone) | More in-reactor tar dissociation onto admix surfaces; that carbon reaches the Primary Cyclone pristine | none |
| Keep the char in the bed — fixed carbon 195 kg/h per Line leaves with the solids | Without bed steam the char is not consumed; carbon product 1, mixed with 212 kg/h mineral | solids carbon/mineral separation spec — OPEN |
| 0.5 atm stays | CH₄ → C + 2 H₂ is mole-increasing; low pressure favours it at the CRSRU too | none |
| Hot-gas booster after the Primary Cyclone (option) | 0.5 atm doubles every downstream volume and costs ~0.9 MW per Line in GPU compression; a 600 °C booster to 1.2 atm costs ~0.15 MW and roughly halves it | CRSRU pressure (OPEN) |
4.3 CRSRU — a dissociation reactor
- Duty: 1.95–2.2 MW thermal per Line at 1,300–1,400 °C (sensible 0.77–0.88, CH₄ dissociation 0.21–0.34, tars −0.085, steam-carbon 0.83, Boudouard 0.13, loss 5 %). 1,300–1,400 °C is the working range; tars dissociate fully in 0.5–2 s there, CH₄ needs the upper end or the non-equilibrium of a plasma. Each 100 °C above 1,300 °C is ~0.1 MW thermal, ~0.17 MW electric.
- Heater: the DC torch (Option C, 1,500 VDC long-arc, N₂ loop, 3.8 MW electric at CENTRAL) is the Gen 1 answer and the only MW-class unit in service. The electrodeless vapour-through-the-head microwave configuration (A2, 3.7 MW) is the clean-sheet target because under this function the electrode fume lands in the carbon product (Option C: Cu 10–50 ppm with a rotated anode, up to ~500 ppm at the literature high end; W 5–50 ppm) and A2 puts no metal in it. TRL 3–4; a test item.
- Carbon formed: 185 kg/h per Line as nanometre carbon black (carbon product 3). Boudouard takes 33 kg/h and steam-carbon 275 kg/h of the hydrocarbon carbon; that is the cost of the oxygen and water that reach the vessel.
4.4 Quench, recovery, capture
Fast quench through 1,200→700 °C: boiler tubes or a recycled-H₂ gas quench keep the carbon dry (the
carbon-black industry's water spray would reintroduce steam onto hot carbon). Quench steam → drying and
WGS. Candle filter after the HRSG (110–260 m² per Line at 0.5 atm; ~half with the booster) collects the
carbon black; no cyclone catches it. The Secondary Cyclone has no carbon duty — retire or keep as a
coarse guard (D-REG-SCOPE-02). Three carbon streams kept apart until the CRSRU carbon has passed metals
separation: REG-CCS-001 (pristine), bed char (with mineral), CRSRU carbon black.
4.5 Gas train
Acid-gas removal (10.5 kg/h HCl, 4 kg/h S) ahead of the shift catalyst and PEM; WGS on the 6.1 mol/s of
dried-off water (shifts 6.1 of 9.4 mol/s CO → H₂ 163 kg/h), plus 3.3 mol/s boiler water to shift the rest
(→ 186 kg/h) or send the residual CO to REG-BSC-001; CO₂ removal (1,070–1,485 kg/h per Line — the oxygen
disposition); PSA; H₂ to the PowerBlock; N₂ to the torch loop (Option C) or none (A2).
5. Product makeup per Line and per Module (W1) [COMPUTED]
| Stream | Per Line (50 TPD) | Per Module (100 TPD) | % of feed |
|---|---|---|---|
| Carbon product 1 — bed char (in 407 kg/h of solids with mineral) | 195 kg/h | 390 kg/h | 9.4 % |
| Carbon product 2 — Primary Cyclone fines (pristine) | within product 1's accounting; split OPEN | ||
| Carbon product 3 — CRSRU carbon black | 185 kg/h | 370 kg/h | 8.9 % |
| Carbon total | 380 kg/h = 9.1 TPD | 18.2 TPD | 18.2 % |
| H₂ to PowerBlock | 163–186 kg/h = 3.9–4.5 TPD | 7.8–8.9 TPD | 7.8–8.9 % |
| CO₂ (oxygen disposition) | 1,070–1,485 kg/h | 2.1–3.0 t/h | 51–71 % |
| Mineral (ash + admix) | 212 kg/h + admix | 10.2 % + | |
| Water: dried moisture 494 → WGS steam 395; residual | |||
| HCl / H₂S / NH₃-derived to acid-gas handling | 10.5 / 4 / ~4 kg/h | ||
| N₂ in loop (Option C only) | 765 Nm³/h circulating, 40–75 make-up |
The published Rev 0 balance (gas 31 %, oil 13 %, water 16 %) has no carbon-black or CO₂ line; this
route replaces the oil line almost entirely with carbon and CO₂. REG-BSO-001 shrinks to a trace.
6. Contamination under this route
| Heater | In the CRSRU carbon black (185 kg/h) | Note |
|---|---|---|
| Option C, 1,500 V, rotated anode | Cu 10–50 ppm, W 5–50 ppm (literature high end: Cu to ~500 ppm) | Carbon-black grades tolerate tens of ppm; graphite precursor needs density separation (W) and the graphitization step (Cu) |
| A1 microwave, clean sheath gas | Si 1–8 ppm, no metal | |
| A2 microwave, vapour through heads | Si 8–75 ppm, no metal | window erosion in tar-laden gas; needs manufacturer data |
| B RF ICP | Si 1–12 ppm, no metal | |
| Any | S and Cl adsorbed from H₂S/HCl — OPEN | carbon-black practice <1 % S; spec-dependent |
Carbon products 1 and 2 never see the heater.
7. Levers if the ~2.6–3 MW per Line deficit must close without external power
| Lever | Gain per Line | Cost |
|---|---|---|
| CRSRU at 1,300 °C with in-reactor CH₄ credit (LOW case) | 0.4 MW | CH₄ dissociation completeness — simulate |
| A2 electrodeless heater (no N₂ to heat, ~61 % to gas) | 0.1–0.3 MW | TRL 3–4 |
| Hot-gas booster after the Primary Cyclone | 0.5–0.7 MW | a 600 °C booster on carbon-laden vapour |
| PEM at 60 % rather than 55 % | 0.3 MW | PowerBlock specification |
| Feed envelope with higher LHV (tyres, plastics) | 1–3 MW | feedstock, not design — the calorific floor |
| All of the above | ~2.3–4.5 MW | closes the gap on paper, not with margin |
Destroying carbon for hydrogen is not on the list.
8. What this route reopens (rulings, not for this sub-session)
- D-65-B function — closed as dissociation by direction; the record text still says reforming.
- D-MCR-FLOW-01 — bed steam injection is contrary to the carbon priority.
- D-46 and the Dense-Phase N₂ Pneumatic Injection System — carrier gas becomes recycled H₂.
- Pregenesis™ design basis Rev 3 — a moisture target (≤5 % proposed) becomes a hard output spec.
- D-REG-SCOPE-02 — Secondary Cyclone role; candle filter not rostered; PTS frame per heater.
- D-ACM-ENERGY-01 / PowerBlock / Island Mode — the ~0.35 MW allowance, the 8 MW per Module basis, external power or a calorific floor on the feed envelope.
- Hydrogen canon wording — "hydrogen and carbon products" vs "Island-Mode fuel, never a product".
- Solids carbon/mineral separation — carbon product 1 is 195 kg/h carbon in 407 kg/h of solids.
- CRSRU pressure — the booster option.
- The CO₂ stream at 1.1–1.5 t/h per Line as a near-zero-claim question for Corpus Zone.
9. Open items this proposal carries
Pregenesis™ moisture target; CRSRU temperature within 1,300–1,400 °C; heater (C now, A2 as test target);
quench medium; carbon-black grade vs graphite-precursor route for product 3; S/Cl on the carbon; the
simulator's CRSRU zone (the dissociation reactions exist in reactions.ts under the code identifier
TAR_CRACKING); and every item in 00_DESIGN_BASIS_COMMON.md §8.