Option C — DC Plasma Torch, N₂ Plasma Gas (D-65-B Locked Baseline) — Rev 1, dissociation basis

Rev 1 working file of the CRSRU heat-source sub-session, rendered as written; linked from MOD-DEF-001 §4.2. File name kept as the page title: C_DC_TORCH_BASELINE.md.

Doc No.CBT-MOD-CRSRU-004
RevisionDesign Zero
StatusDESIGN ZERO — WORKING DESIGN, UNLOCKED
ClassificationISC-2 Confidential
Baseline100 TPD Module · carbon route W1
Design Zero
DESIGN ZERO — WORKING DESIGN, UNLOCKED. Design Zero is unlocked; the Architect locks it when the time is right. Every earlier locked record this design touches is unlocked by CBT-TB-PORTAL-014, not amended. Provenance tags [RULED] [COMPUTED] [INFERRED] [OPEN] [PROPOSED] are kept; under Design Zero a [RULED] tag means ruled by the Architect for Design Zero, not locked. OPEN values are not filled.
Document Control
Document NumberCBT-MOD-CRSRU-004
DesignDesign Zero · 100 TPD Module
Document StatusDESIGN ZERO — WORKING DESIGN, UNLOCKED
OwnerCarbotura Inc. — Engineering; Allen Witters, Lead Systems Architect
ClassificationISC-2 Confidential
AuthorityCBT-TB-PORTAL-014 (Architect, 2026-11-04)
Source of recordCRSRU_HEAT_SOURCE_DESIGN/C_DC_TORCH_BASELINE.md on main
Sub-sessionCRSRU heat-source design ·
Date2026-11-02 (Rev 1) ·
StatusDESIGN INPUT — reference design of the locked baseline, not a ruling
Reads with00_DESIGN_BASIS_COMMON.md Rev 1 (duty cases, vapour, outlet) and CLEAN_SHEET_H2_CARBON.md

Sub-session: CRSRU heat-source design · Date: 2026-11-02 (Rev 1) · For: Allen Witters, Lead Systems Architect Classification: ISC-2 Confidential · Status: DESIGN INPUT — reference design of the locked baseline, not a ruling Reads with: 00_DESIGN_BASIS_COMMON.md Rev 1 (duty cases, vapour, outlet) and CLEAN_SHEET_H2_CARBON.md

Rev 1 changes: duty cases re-based on dissociation (LOW 1.95 / CENTRAL 2.2 / HIGH 2.65 MW thermal per Line at P50); the electrode fume now lands in the CRSRU carbon-black product rather than in the oil and water lines; closed N₂ loop and candle filter included in the budget; GPU dilution restated on the dissociation gas; the filter area corrected from Rev 0.

Provenance tags: [RULED] [COMPUTED] [INFERRED] [OPEN].


1. Principle

A non-transferred DC arc between a tungsten-based cathode and a water-cooled copper anode/nozzle heats N₂ to a bulk 3,000–6,500 K plume, injected into a refractory-lined mixing and dissociation vessel where it mixes with the OmniCrude™ Vapor from the Primary Cyclone and raises the stream to 1,300–1,400 °C. The vapour never passes through the arc. [RULED] as the heat source by D-65-B; contacting [INFERRED]. A different technical domain from the Recyclotron™ (D-65-B). This is exactly the duty of the arc-based methane-to-hydrogen plants at TRL 8–9, which make carbon black with DC torches.

2. Torch count and arrangement [INFERRED]

Item Design
Torches per Line 2, on one Plasma Torch Skid (CBT-ISOFRT-REG-PTS)
Rating, each 3.4 MW arc — one covers P50 CENTRAL alone; both cover P100
Normal operation at P50 Both at ~50 % (1.7 MW arc each): stable band, half the per-torch current (erosion), duty/duty with hot turndown
Arrangement Two tangential plume entries into a cylindrical refractory-lined mixing section, swirl-stabilised; plug-flow dissociation section for 0.5–2 s at ≥1,300 °C; then the Quench Boiler
Materials High-alumina / chrome-alumina refractory over a cooled shell; Cu nozzle; W-La₂O₃ cathode (thoriated avoided — [OPEN])

3. Gas contacting [INFERRED]

Vapour enters axially at 550–650 °C and ~0.5 atm; plumes enter tangentially; swirl mixing brings the bulk to 1,300–1,400 °C in the mixing section. Carbon forms in the bulk as the hydrocarbons dissociate; the water in the vapour reacts with it to CO + H₂ in the same volume. The plume (2–4× hotter than the bulk) sets the refractory hot-spot problem. N₂ is ruled for this option and runs in a closed loop (§6.5).

4. Electrical interface — 800 VDC and 1,500 VDC [INFERRED]

From the 800 VDC device link From the 1,500 VDC zone bus
Converter Buck chopper, arc ≤ ~650 V, ripple <5 %, 3–4 interleaved phases Buck, arc ≤ ~1,250 V; long-arc torch selectable
Arc current, P50 CENTRAL, both torches at 1.7 MW at 550 V: 3,090 A per torch at 1,100 V: 1,545 A per torch
Single torch at 3.4 MW 6,180 A 3,090 A
Fit to NEXUS Z1 as published ICD-NXS-Z1-PBK-001 is a ≤250 kW device link — a 3–7 MW torch load does not fit ICD-NXS-Z1-ZBS-001 1,500 VDC busbar tap, 8 MW per zone — direct zone-bus load
Erosion coupling baseline halves arc current → halves W and Cu source terms

Recommendation for the bus: 1,500 VDC — the LOCKED Module bus (D-PWR-02), the right connector class, and half the erosion. Ignition: HF/HV pilot arc (5–15 kV, <1 kW) with N₂ flowing; chopper limits inrush.

5. Power budget — per Line [COMPUTED]

Chain: thermal-to-gas (design basis §4.2) + N₂ retained at the outlet (1.6 MJ/kg at 1,400 °C) → torch gross → ÷ torch thermal efficiency 78 % (70–85) → ÷ chopper 96 % → + auxiliaries (cooling pumps and coolers, N₂ compression ~0.1 kWh/Nm³, controls) + N₂ loop compressor and candle filter (§6.5). Torch outlet enthalpy 10 MJ/kg N₂ central (range 5–20).

5.1 CENTRAL duty case (1,400 °C)

Line point Thermal to gas N₂ plasma gas N₂ retained Torch gross Arc power DC from bus Aux + loop + filter Operating electrical
P0 0 ~40 kg/h pilot arc — ~0.1 MW 0.1 0.10 0.05 ~0.15 MW
P25 1.1 MW 480 kg/h (385 Nm³/h) 0.21 1.31 1.68 1.75 0.13 1.9 MW
P50 2.2 MW 955 kg/h (765 Nm³/h) 0.42 2.62 3.36 3.50 0.25 3.8 MW
P100 4.4 MW 1,910 kg/h (1,530 Nm³/h) 0.85 5.25 6.73 7.01 0.45 7.5 MW

5.2 Range across duty cases, P50

Duty case Thermal to gas N₂ (Nm³/h) Operating per Line Per Module Per 400 TPD facility
LOW (1,300 °C, CH₄ credit) 1.95 MW 680 3.35 MW 6.7 MW 27 MW
CENTRAL (1,400 °C) 2.2 MW 765 3.8 MW 7.6 MW 30 MW
HIGH (1,800 °C) 2.65 MW 920 4.55 MW 9.1 MW 36 MW

Sensitivity at CENTRAL: at 5 MJ/kg N₂ the flow is 1,920 Nm³/h and operating electrical 4.7 MW; at 20 MJ/kg, 345 Nm³/h and 3.4 MW.

5.3 Register fields, per Line

Field Value Basis
power_kW_rated 7,400 kW (2 × 3.4 MW arc ÷ 0.96 + 0.3 MW auxiliaries) covers P100 CENTRAL
power_kW_operating 3,800 kW at P50 CENTRAL (3,350–4,550 across cases) §5.1–5.2
duty_cycle_pct ~51 % consistent with the 50 %-of-capability design basis

5.4 Against the NEXUS Z1 balance

Facility 27–36 MW against the published 20.48 MW (after magnetrons at 600 kW) — exceeds under every case, and the ~0.35 MW per Module allowance of D-ACM-ENERGY-01 by 20×. The energy ledger in CLEAN_SHEET_H2_CARBON.md §3 shows the Line does not close on this feed; the heater is 60 % of demand.

6. Contamination ledger

6.1 Source term [COMPUTED] from literature rates × design current

W cathode 0.1–1 µg/C; Cu anode 0.2–10 µg/C (0.2 is what a 300–1,000 h commercial anode life implies with magnetic arc rotation; the brief's 1–10 is the un-rotated literature band). Electrode weighing at change-out collapses the range.

Bus Total arc current, P50 CENTRAL W loss Cu loss
800 VDC (550 V arcs) 6,180 A 2.2–22 g/h 4.4–220 g/h
1,500 VDC (1,100 V arcs) 3,090 A 1.1–11 g/h 2.2–110 g/h

6.2 Physical form and where it goes under the dissociation basis [INFERRED]

Electrode metal leaves the arc root as vapour and condenses to sub-micron fume in the 1,300–1,400 °C bulk — in the same volume and at the same time as the 185 kg/h of carbon black forms. The fume nucleates on and co-agglomerates with the carbon. No cyclone catches either (d50 5–10 µm), so the Secondary Cyclone position does not change this. The candle filter after the HRSG collects carbon and fume together; the filter catch is the CRSRU carbon product.

Destination Fraction of fume Basis
CRSRU carbon black (candle filter catch) 70–90 % co-nucleation and filtration
Surfaces (quench boiler, HRSG tubes) 10–25 % thermophoretic deposition
Condenser, acid-gas and water lines <5 % little water remains to wet out
Gas to WGS <1 % residual sub-0.1 µm

6.3 Product consequence [COMPUTED] — the finding that moves under this basis

Bus / anode Cu in carbon black (185 kg/h) W in carbon black
1,500 V, rotated anode (0.2–1 µg/C) 10–50 ppm 5–50 ppm
1,500 V, literature band (1–10 µg/C) 50–500 ppm —
800 V double the above double

Carbon-black grades tolerate tens of ppm of metals; a graphite precursor does not. Cu (b.p. 2,562 °C) volatilises in a 2,800–3,000 °C graphitization step; W (b.p. 5,555 °C) does not — it needs density separation (19.3 vs 2.2 g/cm³) before graphitization. Both are recoverable elements → Metals Refining. Carbon products 1 and 2 (bed char, Primary Cyclone fines) never see the heater and are unaffected. Rev 0's oil/water partition (fume wetting out at the condenser) applied to the reforming basis and is withdrawn.

6.4 Guards

The candle filter is now part of the product train, not a guard. A wet ESP after the condenser (10–30 kW, ROM $0.4–1.0 M per Line) protects the WGS catalyst from the <1 % slip if the product spec demands it.

6.5 Dilution — the N₂ loop [COMPUTED]

Item P50 CENTRAL Range
N₂ plasma gas 765 Nm³/h (955 kg/h) 345–1,920
Dry gas to GPU before shift (H₂ 16.3 + CO 9.4 + N₂ 9.5 + trace) 2,860 Nm³/h
N₂ as fraction of dry gas at REG-GPU-001 27 % 13–45 %
GPU feed compression for the N₂ fraction (0.5 atm → 8 bar, 0.3 kWh/Nm³) ~230 kW 100–580
Loop compressor, GPU N₂ product 1.2 → 5 bar ~80 kW 40–200
Make-up (loop losses, purge of accumulated Ar from air-derived N₂) 40–75 Nm³/h
Candle filter: ΔP 1–3 kPa on the gas mover, blowback N₂, tracing ~25 kW

Loop: GPU N₂ product → REG-BSN → compressor → torches → CRSRU → quench → HRSG → candle filter → condenser → WGS → GPU. The same loop can feed purge and injection if H₂ is not adopted for them (D-46). The GPU is sized for ~27 % inert under this baseline; that sizing is OPEN in tds-001 Rev 0.

Candle filter sizing (corrects Rev 0's 15–25 m²): actual gas volume at 250–450 °C and 0.5 atm is 2.5–3.5 m³/s per Line → 110–260 m² of media at hot-gas face velocities, ~500–900 candles, ROM $1.5–3 M per Line [INFERRED]; about half with the hot-gas booster.

6.6 Ledger rows — ACM Stream Register schema (per Line, P50 CENTRAL, 1,500 V)

stream_id equipment_tag direction medium phase_state rate_kgh rate_Nm3h temp_C press_bara crosses_frame_boundary basis status
CRS-C-N2-IN REG-PTS in N₂ plasma gas (loop) gas 955 (430–2,400) 765 (345–1,920) 20 3–5 yes (PTS ← BSN) 10 MJ/kg INFERRED
CRS-C-W-FUME REG-PTS → REG-CRS out W as sub-µm fume, onto carbon black solid aerosol 0.0011–0.011 — 1,300–1,400 0.5 yes 0.1–1 µg/C × 3,090 A COMPUTED-range
CRS-C-CU-FUME REG-PTS → REG-CRS out Cu as sub-µm fume, onto carbon black solid aerosol 0.0022–0.110 — 1,300–1,400 0.5 yes 0.2–10 µg/C × 3,090 A COMPUTED-range
CRS-C-CB REG-CRS → filter out CRSRU carbon black, Cu 10–500 ppm, W 5–50 ppm solid 185 — 250–450 0.5 yes design basis §5 COMPUTED
CRS-C-CB-SEP filter → density separation → Metals Refining out W-rich heavy fraction; Cu via graphitization solid 0.002–0.1 — ambient 1 yes 70–90 % of fume INFERRED
CRS-C-N2-GPU REG-GPU-001 → REG-BSN out N₂ product to loop gas 955 765 40 8 yes = N2-IN less make-up INFERRED
CRS-C-CW REG-PTS in/out cooling water liquid 27,000–50,000 — 35 / 50 4 yes (NXS-Z2) 0.75–1.3 MW rejected INFERRED
CRS-C-PURGE REG-FDS / airlocks → REG-CRS in purge/injection gas (N₂ or recycled H₂) gas OPEN OPEN 600 0.5 — D-46 OPEN

7. Turndown 0–100 % [INFERRED]

Continuous via current. Both torches at ~95 % (P100), ~50 % (P50), ~25 % or one at 50 % (P25); floor one torch at 30 % ≈ 15 % of P50; hot standby one torch on pilot arc (~100 kW, N₂ ~40 kg/h). Frequent stops cycle the refractory. A torch trip loses 50 % of heat — no graceful degradation.

8. Start-up and ignition [INFERRED]

Vessel pre-heat to ≥800 °C on one torch, N₂ only, isolated from the Recyclotron™ (hours); vapour admitted; torch power follows vapour flow. Restrike after a trip <1 s with N₂ flowing. Loss of N₂ = torch trip → vapour bypass or Line stop; interlock chain OPEN.

9. What the ISO Frame becomes

CBT-ISOFRT-REG-PTS stays a Plasma Torch Skid as rostered: two torch bodies on the CRS vessel, two chopper supplies (~3 t each), DI cooling loop to NXS-Z2, N₂ regulation and loop compressor, electrode service bench. 11–15 t, within a 20 ft envelope [INFERRED]; R1 limits OPEN, no fit claim. Roster unchanged. The candle filter and the N₂ loop are new, unrostered items downstream (Regenesis MAX™).

10. Component-manufacturer anchors

Westinghouse Plasma / Alter NRG MARC series (0.3–2.4 MW); PyroGenesis APT series (to ~1 MW); ScanArc PlasmaGen; Phoenix Solutions; Europlasma — all from memory, verify before citing. The arc-based methane-to-hydrogen plants (TRL 8–9) are the closest service precedent. Minimum two manufacturers at RFQ.

11. TRL and the claims this option can support

Item Rating
Non-transferred DC N₂ torch, 1–3.5 MW TRL 9 as a component
Torch-heated hydrocarbon dissociation to carbon black and H₂ TRL 8–9 in methane service; 6–7 on tar-laden, water-bearing vapour at 0.5 atm
Electrode life in this gas (H₂O/HCl backflow) OPEN
"Established and integrated, no novel components" Supportable for the torch and the duty class; the vessel, quench coupling and N₂ loop are engineering
"No new technical domain" (retired D-65 rationale) Not supportable — D-65-B says so

12. What this option leaves open

Erosion rate in this gas (weigh electrodes); carbon-black grade vs graphite-precursor route for the filter catch; density-separation step; GPU sizing at ~27 % inert; loop and make-up; N₂-loss interlock; cathode material; refractory against plume impingement; duty/duty vs duty/spare.